DEVICE: BIOPSYBELL SRL (08033860038267)
Device Identifier (DI) Information
BIOPSYBELL SRL
RENOVA SPINE KYPHOPLASTY TOOL KIT
In Commercial Distribution
RES1112004V
BIOPSYBELL SRL
RENOVA SPINE KYPHOPLASTY TOOL KIT
In Commercial Distribution
RES1112004V
BIOPSYBELL SRL
KYPHOPLASTY TOOL KIT
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
Yes | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
58031 | Bone access channel kit |
A collection of sterile manual devices intended to create a percutaneous access channel within a vertebral body or other bones (e.g., hand, radius, tibia, calcaneus) prior to the use of an inflatable balloon (e.g., a balloon catheter or balloon tamp) to create a bone space during kyphoplasty/osteoplasty. It typically consists of bone access needles/cannulae, orthopaedic bone wires (Kirschner wires), a drill, and a curette. It is used in orthopaedic surgery, typically under fluoroscopic guidance, to treat a patient diagnosed with compression fractures. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
OCJ | Spinal Channeling Instrument, Vertebroplasty |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
Needle Gauge: 11 Gauge |
Length: 120 Millimeter |
Device Record Status
207b6d24-b0d1-41bb-8c7a-834238966170
October 06, 2022
1
September 28, 2022
October 06, 2022
1
September 28, 2022
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+39 053527850
support@biopsybell.it
support@biopsybell.it