DEVICE: NA (08054242448184)

Device Identifier (DI) Information

NA
F2080P
In Commercial Distribution
F2080P
FIAB SPA
08054242448184
GS1

50
439770017 *Terms of Use
Disposable ECG electrodes with solid gel, round-shaped Ø 40mm, Silver/Silver Chloride(SSC) sensor and stainless steel snap. F2080P model is is made of non woven fabric. The fabric is made of plastic polyethylene fiber (and not natural fiber) that guarantees the transpiration of the skin, but at the same time the resistance to liquids with which they may come into contact during their use. F2080P is suitable for rest, long term, stress or Holter ECG recording, with a direct application onto
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
Yes
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
35035 Electrocardiographic electrode, single-use
A non-sterile, noninvasive electrical conductor designed to conduct electrical signals, generated by a patient's heart, from the skin surface to an electrocardiograph (ECG) monitoring device, via an ECG lead wire (not included). It is typically a disk-like electrode that is affixed to the skin with a special adhesive, adhesive tape, or suction mechanism; a conductive gel may be pre-applied and it may include a skin cleaning wipe to assist electrical connection. Electrocardiography is usually performed using a set of electrodes (e.g., 10) connected to appropriate leads and cables. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
DRX Electrode, Electrocardiograph
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
Yes CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between 5 and 30 Degrees Celsius
Storage Environment Atmospheric Pressure: between 20 and 80 Percent (%) Relative Humidity
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

fb874837-35df-46b8-9781-3acebffdf494
November 18, 2020
2
June 13, 2020
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
18054242448181 24 08054242448184 In Commercial Distribution
28054242448188 10 18054242448181 In Commercial Distribution
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: 78054242448183 CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
+39 0558497943
quality@fiab.it
CLOSE