DEVICE: NA (08054242449655)
Device Identifier (DI) Information
NA
F9089P/100
In Commercial Distribution
F9089P/100
FIAB SPA
F9089P/100
In Commercial Distribution
F9089P/100
FIAB SPA
Disposable ECG pediatric electrodes with solid gel, 36x32mm dimension, Silver/Silver Chloride(SSC) sensor and stainless steel snap. F9089P/100 model are suitable both for rest and stress or Holter ECG recording, with a direct application onto the skin. The SSC sensor permits a reliable and stable recording and permits the signal recovery after defibrillator discharge . The external layer in waterproof medical grade PE foam protects the skin beneath the electrode from air and contaminating fluids.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
Yes | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
35035 | Electrocardiographic electrode, single-use |
A non-sterile, noninvasive electrical conductor designed to conduct electrical signals, generated by a patient's heart, from the skin surface to an electrocardiograph (ECG) monitoring device, via an ECG lead wire (not included). It is typically a disk-like electrode that is affixed to the skin with a special adhesive, adhesive tape, or suction mechanism; a conductive gel may be pre-applied and it may include a skin cleaning wipe to assist electrical connection. Electrocardiography is usually performed using a set of electrodes (e.g., 10) connected to appropriate leads and cables. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
DRX | Electrode, Electrocardiograph |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between 5 and 30 Degrees Celsius |
Storage Environment Atmospheric Pressure: between 20 and 80 Percent (%) Relative Humidity |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
fcf8a958-bedb-45ec-8194-05df987c617d
November 11, 2020
2
June 12, 2020
November 11, 2020
2
June 12, 2020
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
18054242449652 | 20 | 08054242449655 | In Commercial Distribution | ||
28054242449659 | 10 | 18054242449652 | In Commercial Distribution |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
78054242449654
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+39 0558497943
quality@fiab.it