DEVICE: Liofilchem MTS (MIC Test Strip) (08055182872367)
Device Identifier (DI) Information
Liofilchem MTS (MIC Test Strip)
Plazomicin 0.016-256 µg/mL
In Commercial Distribution
$92070-10
LIOFILCHEM SRL
Plazomicin 0.016-256 µg/mL
In Commercial Distribution
$92070-10
LIOFILCHEM SRL
The Liofilchem® MTS™ (MIC Test Strip) is a quantitative method intended for the in vitro determination ofantimicrobial susceptibility of
bacteria MTS™ consists ofspecialized papyr impregnated with a pre-defined concentration gradient ofan antimicrobial agent, which is used to
determine the minimum inhibitozy concentration (MIC) in µglmL ofantimicrobial agents against bacteria as tested on agar media using ovemight
incubation and manual reading procedures. The MTS™ Plazomicin at concentrations of0.016-256 µglmL should be interpreted at 16-20 hours of
incubation.
MTS™ PLZ can be used to dete1mine the MIC ofplazomicin against the microorganisms listed below:
Plazomicin Activity According to the FDA Label
Clinical and in vitro
Enterobacter cloacae
Escherichia coli
Klebsiella pneumoniae
Proteus mirabilis
in vitro only
Citrobacterfreundii
Citrobacter koseri
Klebsiella (Enterobacter) aerogenes
Klebsiella oxytoca
Morganella morganii
Proteus vulgaris
Providencia stuartii
Serratia marcescens
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
63310 | Plazomicin minimum inhibitory concentration (MIC) IVD |
A graduated test strip or collection of reagents containing a specified concentration gradient of the antimicrobial plazomicin, intended to be used to determine the minimum inhibitory concentration (MIC) for a particular microorganism, isolated from a clinical specimen by culture.
|
Obsolete | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
JWY | Manual Antimicrobial Susceptibility Test Systems |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K181708 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between -20 and 8 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
361418a9-0803-4b4a-a557-badc18516d69
October 08, 2018
1
September 06, 2018
October 08, 2018
1
September 06, 2018
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
18055182872364 | 10 | 08055182872367 | In Commercial Distribution | 10 |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
08055182872343
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+390858930745
lassogna@liofilchem.com
lassogna@liofilchem.com