DEVICE: NEAUVIA CELL (08057017760511)

Device Identifier (DI) Information

NEAUVIA CELL
M116I1
In Commercial Distribution
M116I1
EL.EN. SPA
08057017760511
GS1

1
436887608 *Terms of Use
The NEAUVIA CELL is a medical device that used high frequency RF currents to produce a localized increase in temperature in subcutaneous tissue, for temporary relief of pain and muscle spasm and increase local circulation. The device has integrated massaging handpieces intended to provide a temporary reduction in the appearance of cellulite.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
40791 Microwave hyperthermia system applicator, extracorporeal
A component of a microwave hyperthermia system designed to direct and deliver microwave energy used to produce a systemic or local heating effect. It is typically mounted on a floor, wall, or ceiling suspension that allows the operator to position the microwave source from a point outside the patient's body. The applicator assembly includes cables and connectors that interface with the energy-generating unit of the hyperthermia system during treatments. This is a reusable device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
PBX Massager, Vacuum, Radio Frequency Induced Heat
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K183371 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Handling Environment Humidity: between 30 and 75 Percent (%) Relative Humidity
Handling Environment Temperature: between 10 and 35 Degrees Celsius
Storage Environment Atmospheric Pressure: between 70 and 106 KiloPascal
Storage Environment Humidity: between 10 and 90 Percent (%) Relative Humidity
Storage Environment Temperature: between -10 and 50 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

1d2b012d-19d7-429a-908f-85b7759b0e6e
March 16, 2020
1
March 06, 2020
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
No Customer Contact currently defined
CLOSE