DEVICE: FlowArt® (08699443585063)

Device Identifier (DI) Information

FlowArt®
AYWB4010CV
In Commercial Distribution

ASSET MEDIKAL TASARIM SANAYI VE TICARET ANONIM SIRKETI
08699443585063
GS1

1
365581688 *Terms of Use
Three Port Flexible Manifold w/Split Septum Needle-Free Valves and Integrated Back Check Valves
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
Yes
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
42743 Negative-pressure intravenous line needleless valve-connector
A small, stand-alone, Luer-activated needleless plastic valve intended to mate two related intravenous (IV) line devices [e.g., hypodermic syringe and catheter port or tubing from an IV administration set] and hold them in a secured, sealed, locked position until disconnection, at which point negative pressure from the device causes a small volume of retrograde fluid flow into the catheter/tubing. It is intended to eliminate the use of needles for IV administration of medications. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
FPA Set, Administration, Intravascular
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K190806 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: less than 40 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

29d7207a-d0ee-47b7-9a3a-b0afbd111f57
May 09, 2022
1
April 29, 2022
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
28699443585067 50 08699443585063 In Commercial Distribution Box
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
Yes
No CLOSE

Customer Contact

[?]
+1(314) 961-5786
cs@progressivemedinc.com
+1(800) 969-6331
info@assetmedical.com
CLOSE