DEVICE: Leipzig Applicator (08717213009202)

Device Identifier (DI) Information

Leipzig Applicator
085042-02
In Commercial Distribution

Nucletron B.V.
08717213009202
GS1

1
415269930 *Terms of Use
Leipzig Applicator, Ø 20 mm, horizontal
CLOSE

Device Characteristics

MR Unsafe
No
No
No
No
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
38436 General-purpose brachytherapy system applicator, remote-afterloading
A general-purpose remote-afterloading brachytherapy applicator intended to be used to facilitate the delivery of radiation therapy treatments in a range of anatomical regions (e.g., liver, kidneys, lungs, gastrointestinal tract). It is designed for temporary introduction into the body and functions as a guide for computer-controlled placement and removal of single or multiple radioactive sources in a treatment area. This device includes a variety of applicators (e.g., hollow needle, tube, catheter), and their associated components [e.g., introducer sheath, guidewire].
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
JAQ System, applicator, radionuclide, remote-controlled
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Moist Heat or Steam Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Humidity: between 0 and 90 Percent (%) Relative Humidity
Storage Environment Temperature: between 5 and 35 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Outer Diameter: 20.0 Millimeter
CLOSE

Device Record Status

47bb93b1-b847-4c08-bd06-beaebee91f59
September 30, 2019
1
September 21, 2019
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
No
No CLOSE

Customer Contact

[?]
+1(770)300-9725
info.america@elekta.com