DEVICE: N/A (08800019200161)
Device Identifier (DI) Information
N/A
SXG-80R
In Commercial Distribution
ECO-ER-CAT-001S
ECOTRON
SXG-80R
In Commercial Distribution
ECO-ER-CAT-001S
ECOTRON
LINE POWER RATING: 400V3~, 50/60Hz
OUTPUT RATING: 82kW(1000mA@82kV, 800mA@102kV, 500mA@150kV)
KVP range: 40~150kVp
mA range: 10~1000mA
mAs Range: 0.1~500mAs
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
No | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
37604 | Diagnostic x-ray system generator, stationary |
A generator which is an integral component of a stationary diagnostic x-ray system, e.g., a system intended to be operated at a fixed location within a facility or mobile imaging van. It is used to regulate incoming voltage and current to provide an x-ray tube with the power needed to produce an x-ray beam of the desired voltage (kV) and current (mA). It typically comprises a control assembly (console) and high voltage transformer assembly, or it is of a mono-tank generator design and includes transformer, constant potential, inverter and capacitor discharge generator designs.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
IZO | Generator, High-Voltage, X-Ray, Diagnostic |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Humidity: between 5 and 95 Percent (%) Relative Humidity |
Storage Environment Temperature: between -10 and 70 Degrees Celsius |
Handling Environment Humidity: between 30 and 75 Percent (%) Relative Humidity |
Handling Environment Temperature: between 10 and 40 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
Height: 640 Millimeter |
Width: 430 Millimeter |
Length: 620 Millimeter |
Weight: 80 Kilogram |
Device Record Status
652068fa-dd03-42a9-85fd-617ccb73b942
March 29, 2018
2
October 27, 2016
March 29, 2018
2
October 27, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
9999999999
jun1117@ecotron.co.kr
jun1117@ecotron.co.kr