DEVICE: HAD1717MC (08800070400012)
Device Identifier (DI) Information
HAD1717MC
HAD1717MC
In Commercial Distribution
H&abyz Co., Ltd
HAD1717MC
In Commercial Distribution
H&abyz Co., Ltd
The HAD1717MC is a wired digital flat panel X-ray detector.
The HAD1717MC X-ray detector consists of a TFT panel and a scintillator electronic controller, and supports AED (Automatic Exposure Detection) function that can operate without a separate trigger signal. Flat panel sensors for HAD1717MC are fabricated using thin film technology based on amorphous silicon technology, and the sensors are similar to existing photodiode arrays. In this case, each pixel is composed of a photodiode and a thin film transistor (TFT).
Amorphous silicon photodiodes are optimized for green wavelengths and can be used in combination with scintillators such as CsI. The incident X-rays are converted into visible light by the scintillator, and the visible light is stored in an internal capacitor through a photodiode.
Charges charged to capacitors switch TFT gates of panel matrix (panel matrix) and convert them into digital signals on a line and pass them to the control unit.
The digital data generated is then passed to the PC via Ethernet.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
61108 | Indirect flat panel x-ray detector |
An electrically-powered, cassette-like device intended to be used as part of an x-ray system to detect x-ray images following exposure, and create a digital signal; it is not dedicated to imaging of a specific anatomy. It includes two types of transducing technology (i.e., indirect): a scintillator [e.g. caesium iodide (CsI)] screen converts x-ray energy into light, followed by the conversion of light into a digital signal by photodiode array. The image data can be sent to an appropriate processing unit through a wired or wireless connection (e.g., Wi-Fi). It may be used in place of a fixed detector in x-ray imaging systems, e.g., as part of a digital imaging conversion system.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
MQB | Solid State X-Ray Imager (Flat Panel/Digital Imager) |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K200018 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Handling Environment Temperature: between 5 and 40 Degrees Celsius |
Handling Environment Humidity: between 30 and 75 Percent (%) Relative Humidity |
Handling Environment Atmospheric Pressure: between 70 and 106 KiloPascal |
Storage Environment Temperature: between -10 and 50 Degrees Celsius |
Storage Environment Humidity: between 10 and 80 Percent (%) Relative Humidity |
Storage Environment Atmospheric Pressure: between 70 and 106 KiloPascal |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
f71a0ad5-c6a1-4b5c-ac5e-d5566f9da52f
April 17, 2023
1
April 07, 2023
April 17, 2023
1
April 07, 2023
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found