DEVICE: CASSIOPEIA Cervical Plate System (08806395497119)

Device Identifier (DI) Information

CASSIOPEIA Cervical Plate System
3300-5117
In Commercial Distribution
3300-5117
GS Medical Co., Ltd.
08806395497119
GS1

1
688385418 *Terms of Use
The CASSIOPEIA Cervical Plate System is a multiple component system that comprises several sizes of plates and screws and associated manual surgical instruments. The MVP Cervical Plate System implants are supplied non-sterile, are single use, and are fabricated from medical grade titanium alloy (Ti6Al4V ELI, ASTM F 136) The MVP Cervical Plate System is intended for anterior cervical fixation (C2-C7) in skeletally mature patients as an adjunct to fusion for the following indications: Degenerative disc disease (defined as neck pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), Spondylolisthesis, Trauma (including fracture or dislocation), Spinal stenosis, Deformities or curvatures (kyphosis, lordosis, or scoliosis), Tumors, Pseudoarthrosis and Failed previous fusion.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. The copyright and database rights in the original GMDN materials are owned by The GMDN Agency Ltd 2005-2023. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
46653 Spinal fixation plate, non-bioabsorbable
A small, implantable, non-customized sheet of solid material intended to be attached to the spine with screws for spinal immobilization; it is made of a material that is not chemically degraded or absorbed via natural body processes (includes implant grade metal such as surgical steel, titanium alloy, or carbon fibre). The device is typically used to provide immobilization and stabilization of spinal segments in the treatment of various spinal instabilities or deformities (e.g., during anterior/posterior cervical, anterior/posterior lumbar, thoracolumbar, and occipital fixation procedures).
Active true
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
KWQ Appliance, Fixation, Spinal Intervertebral Body
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K190170 000
No CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Moist Heat or Steam Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

4ecc074f-2546-4438-93b2-0aa7f113a3d0
September 18, 2023
4
June 18, 2019
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
Yes
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
Yes
No CLOSE

Customer Contact

[?]
+82432377393
udimail@gsmedi.com