DEVICE: Image-intensified fluoroscopic x-ray system, mobile (08809246620025)

Device Identifier (DI) Information

Image-intensified fluoroscopic x-ray system, mobile
KMC-650
In Commercial Distribution
KMC-650
GEMSS MEDICAL SYSTEMS CO.,LTD.
08809246620025
GS1

1
689163897 *Terms of Use
The KMC-650 is a great solution to produce radiological images of patient during medical operations. This inverter control X-ray unit visualizes the anatomical structure on screen, which is obtained by X-ray fluoroscopy and the image intensifier. This system can be applied in emergency room, operation room, cast room or etc. of hospital.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
No
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
37646 Mobile general-purpose fluoroscopic x-ray system, digital
A mobile (within an imaging facility) general-purpose diagnostic fluoroscopic x-ray system that uses a C-arm and digital techniques for image capture, display and manipulation and is designed to be used in a variety of general-purpose applications requiring real-time fluoroscopic imaging capabilities. It includes spot-film capabilities in addition to the fluoroscopic features and is intended to optimize the capability of users to visually and quantitatively evaluate the anatomy and physiological function of various targeted body areas in real-time. It is frequently used in conjunction with an ingested or injected x-ray contrast medium. Images can be both real-time and delayed formats.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
JAA System, X-Ray, Fluoroscopic, Image-Intensified
OXO Image-Intensified Fluoroscopic X-Ray System, Mobile
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K160065 000
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Temperature: between 10 and 40 Degrees Celsius
Handling Environment Humidity: between 30 and 75 Percent (%) Relative Humidity
Handling Environment Atmospheric Pressure: between 50 and 106 KiloPascal
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

30458feb-9880-4760-9472-5bf21bb27b49
July 06, 2018
3
September 24, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
Yes
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
+82317372211
sangwoo@gemss-medical.com
CLOSE