DEVICE: VivAer® Stylus (08886479300269)

Device Identifier (DI) Information

VivAer® Stylus
FG1787
In Commercial Distribution
CAT1785
Aerin Medical Inc.
08886479300269
GS1

1
051512253 *Terms of Use
The VivAer® Stylus is a disposable handheld device capable of delivering bipolar radiofrequency energy to tissue. The VivAer® Stylus consists of a handle, shaft and treatment tip. An array of bipolar electrodes is positioned on a nonconductive tip which is attached to a handle via a nonconductive shaft. A temperature sensor is located on the tip to monitor tissue temperature. The Stylus is attached to a Temperature controlled radiofrequency generator (Aerin Console) via a flexible cable.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
44776 Electrosurgical system
An assembly of devices intended to generate, and apply radio-frequency (RF) alternating current to soft tissues for cutting and coagulation during an endoscopic or open surgical procedure; it is not dedicated to focal ablation of specific tissues (i.e., not a radio-frequency ablation system). The assembly includes a mains electricity-powered (AC-powered) RF generator with monitoring functions/controls, connection cables, a handpiece, and electrodes to apply the energy to the surgical site. Tissue resistance to the electrical current creates the heat as the current travels through the body between electrodes; it is not intended for inert gas-enhanced electrosurgery.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
GEI Electrosurgical, Cutting & Coagulation & Accessories
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K200300 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Humidity: between 20 and 85 Percent (%) Relative Humidity
Handling Environment Temperature: between 5 and 40 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

83ec2a27-a23f-405e-9fd4-06dc1722e801
January 15, 2024
1
January 05, 2024
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
833-484-8237