DEVICE: Mi1000 MED-EL CONCERT +FLEXsoft (09008737062767)

Device Identifier (DI) Information

Mi1000 MED-EL CONCERT +FLEXsoft
06276
Not in Commercial Distribution
07674
Med-El Elektromedizinische Geräte Gesellschaft m.b.H.
09008737062767
GS1
May 02, 2024
1
300764032 *Terms of Use
Cochlear Implant
CLOSE

Device Characteristics

MR Conditional
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
47373 Cochlear implant system electrode array assembly
The implantable portion of a cochlear implant system [cochlear implant (CI)] that typically consists of an electrically-powered electrode array surgically implanted in one cochlea, and a receiver-stimulator implanted in the skull near the ear and connected to the electrode array; it does not elute a drug. Electrical signals are transmitted from the external portion of the device to the receiver-stimulator and ultimately to the cochlea, via the electrode array, for the partial restoration of auditory sensation in a severely/profoundly deaf person. Dedicated implantation instruments may be included.
Active true
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
MCM Implant, Cochlear
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
P000025 094
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Temperature: between -20 and 55 Degrees Celsius
Handling Environment Temperature: between -4 and 131 Degrees Fahrenheit
Special Storage Condition, Specify: The sterilized implant may only be stored in this sterile packaging inside the Implant Box at room temperature until the stated expiry date.
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

fa6bc6a5-04a9-4062-ac71-86d543a2eac8
May 07, 2024
5
April 19, 2018
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
Yes
Yes
No CLOSE

Customer Contact

[?]
1-888-633-3524
implants.us@medel.com
CLOSE