DEVICE: CardioCel 3D (09348992000334)

Device Identifier (DI) Information

CardioCel 3D
UC0405A30
In Commercial Distribution
C0405A30
ADMEDUS REGEN PTY LTD
09348992000334
GS1

1
741172167 *Terms of Use
CardioCel® 3D is prepared from bovine pericardium using the ADAPT® Tissue Processing Technology. The pericardium is procured from cattle originating in Australia. Australia is considered as being of negligible risk for BSE. The device is a sterile, off-white, moist, pre-cut, flat or curved sheet of acellular collagen, presented sterile in a solution of propylene glycol and sealed in a container impermeable to air and moisture.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. The copyright and database rights in the original GMDN materials are owned by The GMDN Agency Ltd 2005-2023. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
35273 Cardiovascular patch, animal-derived
An implantable material designed to reinforce suture lines and/or increase the strength of weak or injured cardiac and/or peripheral vascular tissues during cardiovascular repair/reconstruction procedures (e.g., annulus or septal defect repair, endarterectomy, profundaplasty). It is a patch made of, or coated/impregnated with, materials of animal origin (e.g., porcine, bovine, or equine pericardium/collagen), that is typically implanted with sutures.
Active true
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
PSQ Intracardiac Patch Or Pledget, Biologically Derived
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K170951 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Temperature: between 2 and 25 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Width: 4 Centimeter
Length: 5 Centimeter
Angle: 30 degree
CLOSE

Device Record Status

a6a92888-642e-488e-b8d7-4ca5902fd135
February 05, 2021
2
September 07, 2018
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
Yes
Yes CLOSE

Customer Contact

[?]
+61892660100
info@admedus.com
CLOSE