DEVICE: Integra® (10381780033172)
Device Identifier (DI) Information
Integra®
901118
Not in Commercial Distribution
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
901118
Not in Commercial Distribution
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
The 46 cm Peritoneal Introducer Sheath is designed to be used with a Peritoneal Introducer of appropriate length (46 cm) during the placement of a peritoneal drainage catheter in the treatment of hydrocephalus. It features a tapered tip to facilitate subcutaneous insertion and passage.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
Yes | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
46801 | Subcutaneous tunneller, single-use |
A hand-held manual surgical instrument designed to create a subcutaneous tunnel (artificial passageway) between percutaneous entry and exit incisions for the subcutaneous placement of a device (e.g., catheter for medication administration, shunt). It is available in a variety of forms and may be: 1) a luminal sheath with a removable inner obturator, intended for co-axial device introduction, followed by sheath removal; or 2) a non-luminal device intended to either lead or pull the device through subcutaneous tissue. It is not intended for tunnelling through deep tissues and is not a dedicated pacing or defibrillation lead tunneller. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
GYK | Instrument, shunt system implantation |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K771529 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
Device Size Text, specify: 46cm Length x 4.3mm I.D. |
Device Record Status
116026dd-75e6-4cd8-9b44-b001596230c5
February 05, 2024
5
September 01, 2016
February 05, 2024
5
September 01, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
30381780033176 | 5 | 10381780033172 | 2021-12-31 | Not in Commercial Distribution | BOX |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
HIBCC | M2729011181 |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)654-2873
custsvcnj@integralife.com
custsvcnj@integralife.com