DEVICE: External Drainage Set (10381780035565)
Device Identifier (DI) Information
External Drainage Set
910120A
Not in Commercial Distribution
910120A
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
910120A
Not in Commercial Distribution
910120A
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
The External Drainage Set (EDS) consists of: an extension tubing line with a T fitting and a four-way stopcock; a one-piece drainage tube assembly, including a patient line with a T fitting, a tubing, an antireflux valve, a 75 ml cylinder and a drainage tubing; a drainage bag with female luer lock connector, a suspension hook and a hydrophobic filter; a 350 mm H2O drainage pressure scale. A Lumbar Catheter Accessory Kit (LCAK).
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
Yes | |
Yes | |
Yes | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
61797 | Lumbar cerebrospinal fluid drainage catheterization kit |
A collection of sterile devices intended for short-term percutaneous access to the subarachnoid (intrathecal) or epidural space of the lumbar spinal column to drain cerebrospinal fluid (CSF) as a means of reducing CSF volume and intracranial pressure (ICP). It includes a spinal infusion/drainage catheter and devices intended for catheter insertion (e.g. Tuohy needle, suture, guidewire) and CSF collection (e.g., drip chamber, drainage bag, tubing set, filter). This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
JXG | Shunt, central nervous system and components |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Special Storage Condition, Specify: Do not expose to temperatures exceeding 60 degrees Celsius (140 degrees Fahrenheit). |
Clinically Relevant Size
[?]Size Type Text |
---|
Device Size Text, specify: Cylinder 75ml, Drainage Bag 500ml , Lumbar Cath. 80cm Length x 1.6mm O.D. x 0.8mm I.D. (F5), 14G Tuohy Needle |
Device Record Status
1c5d85d1-d248-4e32-b6e9-e9016a11b36d
December 23, 2024
5
October 01, 2015
December 23, 2024
5
October 01, 2015
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
HIBCC | M272910120A1 |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)654-2873
custsvcnj@integralife.com
custsvcnj@integralife.com