DEVICE: External Drainage Set (10381780035565)

Device Identifier (DI) Information

External Drainage Set
910120A
Not in Commercial Distribution
910120A
INTEGRA NEUROSCIENCES IMPLANT (FRANCE)
10381780035565
GS1
December 31, 2021
1
531408342 *Terms of Use
The External Drainage Set (EDS) consists of: an extension tubing line with a T fitting and a four-way stopcock; a one-piece drainage tube assembly, including a patient line with a T fitting, a tubing, an antireflux valve, a 75 ml cylinder and a drainage tubing; a drainage bag with female luer lock connector, a suspension hook and a hydrophobic filter; a 350 mm H2O drainage pressure scale. A Lumbar Catheter Accessory Kit (LCAK).
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
Yes
Yes
Yes
No
Yes
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
61797 Lumbar cerebrospinal fluid drainage catheterization kit
A collection of sterile devices intended for short-term percutaneous access to the subarachnoid (intrathecal) or epidural space of the lumbar spinal column to drain cerebrospinal fluid (CSF) as a means of reducing CSF volume and intracranial pressure (ICP). It includes a spinal infusion/drainage catheter and devices intended for catheter insertion (e.g. Tuohy needle, suture, guidewire) and CSF collection (e.g., drip chamber, drainage bag, tubing set, filter). This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
JXG Shunt, central nervous system and components
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Special Storage Condition, Specify: Do not expose to temperatures exceeding 60 degrees Celsius (140 degrees Fahrenheit).
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify: Cylinder 75ml, Drainage Bag 500ml , Lumbar Cath. 80cm Length x 1.6mm O.D. x 0.8mm I.D. (F5), 14G Tuohy Needle
CLOSE

Device Record Status

1c5d85d1-d248-4e32-b6e9-e9016a11b36d
December 23, 2024
5
October 01, 2015
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
HIBCC M272910120A1
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
Yes
No CLOSE

Customer Contact

[?]
+1(800)654-2873
custsvcnj@integralife.com