DEVICE: CUSA® NXT (10381780039525)

Device Identifier (DI) Information

CUSA® NXT
NXT00005
Not in Commercial Distribution
NXT00005
INTEGRA LIFESCIENCES (IRELAND) LIMITED
10381780039525
GS1
September 03, 2024
2
989925396 *Terms of Use
CUSA® NXT Contamination Guard
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
44778 Soft-tissue ultrasonic surgical system
An assembly of devices that converts high frequency current into ultrasonic oscillation to mechanically fragment soft-tissue cells upon contact with a vibrating tip for cutting and/or coagulating tissue during surgery, possibly in combination with irrigation and aspiration. Ongoing vibration may create heat in cells (diathermy) to increase the cutting/coagulating capacity. It typically includes an energy-producing generator with monitoring functions, a handpiece(s) with tip(s) to convert and apply the energy, connecting cables, a foot-switch as an option to regulate the energy, and possibly an integrated irrigation/suction system.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
LFL Instrument, ultrasonic surgical
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Special Storage Condition, Specify: Temperature -20°C to 60°C; Relative Humidity 25 to 85%; Atmospheric Pressure 500hPa to 1100hPa;Keep Dry.
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

4a9fe769-7b33-4ed3-80c7-f0e080f9ceee
October 28, 2024
6
January 27, 2017
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
HIBCC M433NXT000051
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: 00381780039528 CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
No
No CLOSE

Customer Contact

[?]
+1(800)654-2873
custsvcnj@integralife.com
CLOSE