DEVICE: Integra® MOVEMENT® Great Toe System (10381780116400)

Device Identifier (DI) Information

Integra® MOVEMENT® Great Toe System
MGT89010MT
In Commercial Distribution
MGT89010MT
Ascension Orthopedics, Inc.
10381780116400
GS1
December 31, 2026
1
942377524 *Terms of Use
The Integra Movement Great Toe System metatarsal component is designed for resurfacing the 1st metatarsal head. The component is an anatomically designed, monolithic device.The device is made from cobalt chromium alloy with a commercially pure titanium plasma spray. The metatarsal is intended as hemi-arthroplasty at the surface and is a press-fit.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
33700 Total metatarsophalangeal joint prosthesis, one-piece
An implantable device designed to replace the metatarsophalangeal (MTP) joint(s) of the foot (toe). The device is made of a single piece of silicone elastomer. It is is intended to treat degenerative or traumatic arthritis, hallux valgus, hallus rigidus, and/or an unstable or painful MTP joint.
Active true
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
KWD PROSTHESIS, TOE, HEMI-, PHALANGEAL
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K092047 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify: .566 in L; Size 10
CLOSE

Device Record Status

309841d0-6eba-4fb8-8197-2701cbbe7521
January 25, 2023
5
October 09, 2017
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
HIBCC M268MGT89010MT1
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
+1(800)654-2873
custsvcnj@integralife.com
CLOSE