DEVICE: Integra® Jarit® (10381780134503)
Device Identifier (DI) Information
Integra® Jarit®
653101
In Commercial Distribution
653101
INTEGRA LIFESCIENCES PRODUCTION CORPORATION
653101
In Commercial Distribution
653101
INTEGRA LIFESCIENCES PRODUCTION CORPORATION
Integra® Jarit® Fan Retractor, Five Fingers, 0-45°
Device Characteristics
| Labeling does not contain MRI Safety Information | |
| No | |
| No | |
| No | |
| Yes | |
| No | |
| No | |
| No | |
| No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 35080 | Rigid endoscopic tissue manipulation forceps, reusable |
A rigid, hand-held manual surgical instrument designed to be introduced through the working channel of an endoscope and/or an endoscopic port (e.g., laparoscopic port) primarily for grasping and manipulating tissues during endoscopic surgery. It has proximal controls (e.g., scissors-like handles), a rigid long slender shaft, and distal grasping jaws; it is not an electrosurgical device and is not dedicated to biopsy. This is a reusable device.
|
Active | false |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| GAD | RETRACTOR |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| Premarket Submission Number Not Available/Not Released | |
Sterilization
Storage and Handling
[?]| Storage and Handling |
|---|
| No storage/handling found |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| Outer Diameter: 5 Millimeter |
| Device Size Text, specify: 2-1/8" |
| Device Size Text, specify: 13-1/4" |
Device Record Status
e63bf3c4-fe65-4178-8baf-eb6a36b7469c
November 30, 2023
8
January 15, 2018
November 30, 2023
8
January 15, 2018
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| No Package DIs found | |||||
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| HIBCC | M2746531011 |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)654-2873
custsvcnj@integralife.com
custsvcnj@integralife.com