DEVICE: Ascension® (10381780235057)
Device Identifier (DI) Information
Ascension®
PYROMCPINSTP
Not in Commercial Distribution
Ascension Orthopedics, Inc.
PYROMCPINSTP
Not in Commercial Distribution
Ascension Orthopedics, Inc.
The Ascension MCP is indicated for use as a total joint replacement of index, long, ring, and small finger metacarpophalangeal (MCP) joints that exhibit symptoms of pain, limited motion, or inadequate bony alignment secondary to articular destruction or degenerative disease related to rheumatoid arthritis, systemic lupus erythematosus, osteoarthritis, or post-traumatic arthritis where soft tissue reconstruction can provide adequate stabilization. The set includes proximal trials, distal trials, and silicone trials to evaluate the size and fit of the appropriate implant. Instruments are included to assist with the trials.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
44758 | General external orthopaedic fixation system implantation kit, reusable |
A collection of mostly instruments intended to be used to manipulate and prepare soft-tissue and bone for the adjustment or placement of the implantable components of an external orthopaedic fixation system in various skeletal areas (e.g., bones of limbs, spine, pelvis, craniomaxillofacial areas). It is a non-dedicated device that includes various metallic and/or plastic reusable devices (e.g., retractors, rods, clamps, drills, pins, cutters, screwdrivers, guides, tighteners) that are specific to the fixation system applied; the implant(s) is not included. This is a reusable device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
KYJ | PROSTHESIS, FINGER, CONSTRAINED, POLYMER |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K022892 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
Device Size Text, specify: 21.7 in L x 10.0 in W x 2.4 in H |
Device Record Status
4d4ced5a-7882-4da8-b7b3-0a09d255ac9c
May 02, 2023
4
August 15, 2016
May 02, 2023
4
August 15, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
HIBCC | M268PYROMCPINSTP1 |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found