DEVICE: Titan™ (10381780235583)

Device Identifier (DI) Information

Titan™
TRL-0923-010-4216E
In Commercial Distribution
TRL-0923-010-4216E
Ascension Orthopedics, Inc.
10381780235583
GS1
December 31, 2026
1
942377524 *Terms of Use
The Eccentric Head Trial is used to evaluate the size and fit of the implant.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
58784 Humeral head prosthesis trial, reusable
A copy of a final humeral head prosthesis designed to be used before primary or revision implant surgery to validate the proper size of the permanent prosthesis required by the patient, to ensure its proper orientation and positioning, and to verify that the implant site has been cut to the proper dimensions. It has a cup-like ball shape and is available in types such as concentric head fixation, eccentric head fixation, cuff tear arthropathy (CTA), or types for revision surgery. It is typically made of metal and/or polymer. This is a reusable device intended to be sterilized prior to use.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
HWT TEMPLATE
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
Yes CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Moist Heat or Steam Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify: 1.7 in dia x .63 in H
CLOSE

Device Record Status

eefb1e7c-fffb-44fb-b89e-e97381d0d562
January 25, 2023
7
August 15, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
HIBCC M269TRL09230104216E1
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
No
No CLOSE

Customer Contact

[?]
+1(800)654-2873
custsvcnj@integralife.com