DEVICE: Titan™ (10381780245858)
Device Identifier (DI) Information
Titan™
INS096004901
In Commercial Distribution
INS-0960-049-01
Ascension Orthopedics, Inc.
INS096004901
In Commercial Distribution
INS-0960-049-01
Ascension Orthopedics, Inc.
Titan™ Reverse Shoulder System
The reamer guide body inserter/extractor is used to assist with the preparation and placement of trials and implants in the reverse shoulder system.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
12696 | Orthopaedic inorganic implant inserter/extractor, reusable |
A hand-held manual surgical instrument designed for the surgical insertion and/or extraction of a non-tissue based (inorganic) orthopaedic implant (e.g., a bone nail, spiral blade, or bone fixation plate). It is an instrument in a one-piece or modular configuration with a region that will attach/fit/lock to part of the implant, and typically features either a mechanism to apply a striking force (e.g., on a pad/flange) a mechanism for twisting (screwing) (e.g., T-handle), or a plunger mechanism to deploy a guide to drive the implant into place. This is a reusable device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
HWB | EXTRACTOR |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
Device Size Text, specify: 8.63 in L |
Device Record Status
9fbe142c-3694-4693-9561-184bda3c5aa6
September 11, 2024
8
August 30, 2017
September 11, 2024
8
August 30, 2017
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
HIBCC | M269INS0960049011 |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)654-2873
custsvcnj@integralife.com
custsvcnj@integralife.com