Titan™ Total Shoulder System The cemented long stem reamer is used to compress and/or remove bone to create a cavity of proper shape and size.
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
45114 Bone-resection orthopaedic reamer, reusable
An orthopaedic surgical instrument intended to resect bone (cut out part of the bone), and in some cases hypertrophic tissue [e.g., ligamentum flavum], to: 1) accept a prosthetic implant, typically at or within a joint (e.g., condyle of knee, neck of humerus, olecranon of ulna); and/or 2) relieve pressure at or facilitate access to a joint. Commonly called a mill or a reamer, it is typically designed as a stainless steel cylindrical body with an end/circumferential cutting edge and is attached to a shaft for manual or powered rotation. This is a reusable device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
HTO REAMER
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
Yes CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Moist Heat or Steam Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Device Size Text, specify: .552 in dia x 6.5 in flute L
CLOSE

Device Record Status

76dc20af-d28f-454d-a876-1e50864ce40a
October 04, 2023
7
August 30, 2017
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
HIBCC M269RMR0950025141651
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
+1(800)654-2873
custsvcnj@integralife.com
CLOSE