DEVICE: CUSA® Clarity (10381780466147)
Device Identifier (DI) Information
CUSA® Clarity
C7401S
In Commercial Distribution
C7401S
INTEGRA LIFESCIENCES (IRELAND) LIMITED
C7401S
In Commercial Distribution
C7401S
INTEGRA LIFESCIENCES (IRELAND) LIMITED
CUSA® Clarity Standard Tip
Device Characteristics
MR Unsafe | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
44755 | Soft-tissue ultrasonic surgical system handpiece tip, single-use |
A sterile removable endpiece intended to be attached to an ultrasonic surgical system handpiece, and makes contact with a patient while oscillating (vibrating) at high frequency in order to fragment soft-tissue cells for cutting and/or coagulating tissue during surgery. The device comes in a variety of forms (e.g., blade, cylinder, pincers) and sizes, and is typically made of metal; it is not intended to be held directly (i.e., does not include a holder). This device is utilized in a variety of surgical disciplines (e.g., neurosurgery, general surgery, surgical oncology, gynaecology, and urology). This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
LBK | Device, neurosurgical fragmentation and aspiration |
LFL | Instrument, ultrasonic surgical |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Special Storage Condition, Specify: Keep Dry, Do not use if package is damaged |
Storage Environment Atmospheric Pressure: between 500 and 1060 millibar |
Handling Environment Temperature: between 10 and 35 Degrees Celsius |
Handling Environment Humidity: between 30 and 85 Percent (%) Relative Humidity |
Storage Environment Humidity: between 15 and 85 Percent (%) Relative Humidity |
Storage Environment Temperature: between -18 and 60 Degrees Celsius |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
1c9a484b-172d-4388-8beb-65edb5073d0c
April 14, 2023
4
January 16, 2019
April 14, 2023
4
January 16, 2019
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
30381780466141 | 5 | 10381780466147 | In Commercial Distribution | Box |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)654-2873
custsvcnj@integralife.com