DEVICE: Integra® MicroFrance® (10381780490401)

Device Identifier (DI) Information

Integra® MicroFrance®
MCEN189LP
In Commercial Distribution
MCEN189LP
INTEGRA LIFESCIENCES PRODUCTION CORPORATION
10381780490401
GS1

1
081277700 *Terms of Use
LOANER Wormald Hemorrhage Control (Vascular Clamps) Kit
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
Yes
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
35798 Open-surgery ligation clip applier
A hand-held manual surgical instrument designed to apply small atraumatic clips (not included) for the ligation of blood vessels, or similar tubular anatomy, mainly to prevent and/or stop bleeding (i.e., haemostasis) during an open-surgery procedure. It may also be used to apply small clamps (e.g., bulldog type) to tissues however it is not intended to apply an aneurysm clip. The device is typically a metallic instrument with flat, curved ends to hold and deliver the clips (e.g., forceps-like); implantable clips are not included. This is a reusable device after sterilization.
Active false
35350 Nasal speculum, reusable
A hand-held surgical instrument inserted into a nostril and manually expanded to maximally open the nostril by stretching the tissue around the nasal orifice, allowing access for examination or ear/nose/throat (ENT) surgical intervention. The device is made of high-grade stainless steel and has two blunt, contoured blades that are expanded by applying pressure to the pivoted handles. The handles are typically attached to springs so that they close upon release of the pressure applied to them. This is a reusable device.
Active false
12143 Instrument tray, reusable
A container intended to provide a suitable platform for placing/containing many medical/surgical/dental instruments and related items for use during a clinical procedure; it might, in addition, be used during, but not dedicated to, reprocessing/sterilization procedures. It is a receptacle in one of a variety of designs, typically with moulded positions for placing the instruments; it might include a lid and/or removable identification tags. This is a reusable device.
Active false
38727 General-purpose surgical scissors, reusable
A hand-held manual surgical instrument designed to cut/dissect a variety of tissues during open surgery and having no dedication to a specific anatomy or clinical use; it might in addition be intended for cutting materials associated with surgery (e.g., sutures). It is comprised of two pivoted shearing blades with handles, whereby the blades cut as the sharpened edges pass one another as they are closed; some types may have blades that cross over to expose a sharp edge for slicing tissue like a scalpel. It is typically made of metal and is available in various designs and sizes, and some types can have carbide inserts along the cutting edges. This is a reusable device.
Active false
62468 Surgical soft-tissue manipulation forceps, scissors-like, reusable
A hand-held, manual, open-surgery instrument designed to grasp, manipulate, dissect, and/or clamp soft-tissues (e.g., organs, blood vessels); it is not intended for grasping/clamping bone or teeth, nor is it dedicated to ophthalmic surgery and is not a dedicated biopsy device. It has a scissors-like hinged design with ring handles and blades (non-cutting) that may be available in a range of sizes or designs. It may be intended for use at a specific anatomy. This is a reusable device intended to be sterilized prior to use.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
MDM INSTRUMENT, MANUAL, SURGICAL, GENERAL USE
MMO TRAY, SURGICAL, ENT
DXC CLAMP, VASCULAR
LRC INSTRUMENT, ENT MANUAL SURGICAL
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Moist Heat or Steam Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

5ebd1f33-100b-4c30-9a03-624be1665ab6
December 06, 2022
12
September 14, 2018
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
No
No CLOSE

Customer Contact

[?]
+1(800)654-2873
custsvcnj@integralife.com