DEVICE: ARROW (10801902167733)
Device Identifier (DI) Information
ARROW
IPN915319
In Commercial Distribution
IAB-05840-LWS
TELEFLEX INCORPORATED
IPN915319
In Commercial Distribution
IAB-05840-LWS
TELEFLEX INCORPORATED
RediGuard(R) IAB
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
34919 | Intra-aortic balloon catheter |
A flexible, balloon-tipped, tube that is placed in the aorta distal to the aortic valve to augment the heart's pumping capability. It is typically introduced percutaneously via one of the femoral arteries and advanced to the descending thoracic aorta using fluoroscopic imaging guidance. Once positioned, an external pump alternately inflates and deflates the balloon in a cycle counter to the cardiac cycle (counter pulsation), facilitating ejection during systole and limits regurgitation during diastole. It is used to treat several cardiovascular conditions, e.g., after open-heart surgery, cardiogenic shock, intractable angina, or to reduce myocardial conditions. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
DSP | System, balloon, intra-aortic and control |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Special Storage Condition, Specify: Store at normal room temperature away from direct exposure to light. Prolonged exposure to fluorescent light, sunlight or heat will damage the balloon |
Clinically Relevant Size
[?]Size Type Text |
---|
Catheter Gauge: 8 French |
Device Record Status
1a8d3da3-0788-4369-8602-2ac985eef607
November 06, 2023
4
July 06, 2020
November 06, 2023
4
July 06, 2020
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(919)544-8000
CS@TELEFLEX.COM
CS@TELEFLEX.COM