DEVICE: ARROW (10801902180817)
Device Identifier (DI) Information
ARROW
IPN917238
In Commercial Distribution
AI-07132
TELEFLEX INCORPORATED
IPN917238
In Commercial Distribution
AI-07132
TELEFLEX INCORPORATED
Berman Angiographic Balloon Catheter
Device Characteristics
| Labeling does not contain MRI Safety Information | |
| Yes | |
| No | |
| Yes | |
| Yes | |
| No | |
| No | |
| No | |
| No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 35889 | Pulmonary artery balloon catheter, non-electrical |
A flexible, non-electrical tube with an inflatable balloon at its distal tip designed to be introduced percutaneously into the venous system via a central vein (e.g., jugular, subclavian), and advanced from the superior vena cava to the pulmonary artery, to measure/monitor a haematological parameter(s) [e.g., pulmonary arterial pressures (e.g., wedge), stroke volume] via the pressure changes at its distal tip. Also referred to as a Swan-Ganz catheter, it is typically used in conjunction with a parent device (e.g., external blood pressure transducer) and may include devices dedicated to introduction. This is a single-use device.
|
Active | false |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| DYG | CATHETER, FLOW DIRECTED |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| K892530 | 000 |
Sterilization
Storage and Handling
[?]| Storage and Handling |
|---|
| Special Storage Condition, Specify: Store at normal room temperature away from direct exposure to light. Prolonged exposure to fluorescent light, sunlight or heat will damage the balloon |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| Catheter Gauge: 7 French |
| Length: 90 Centimeter |
Device Record Status
dee4f677-28d7-41e3-bee3-af75b7861b58
December 04, 2023
3
August 19, 2021
December 04, 2023
3
August 19, 2021
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| 20801902180814 | 5 | 10801902180817 | 2022-09-13 | Not in Commercial Distribution | Case |
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| No Secondary DIs found | |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(919)544-8000
CS@TELEFLEX.COM
CS@TELEFLEX.COM