DEVICE: 2.0mm Drill (10812269025543)

Device Identifier (DI) Information

2.0mm Drill
MDS101120100
In Commercial Distribution
MDS101120100
MIAMI DEVICE SOLUTIONS LLC
10812269025543
GS1

1
078703080 *Terms of Use
2.0mm Drill, 100mm
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
47563 Fluted surgical drill bit, single-use, non-sterile
A non-sterile shaft of metal with an obtuse, V-shaped cutting edge designed to be rotated to bore into bone to create a hole of the same dimension as the diameter of the shaft. This device, commonly called a "twist drill", has a cylindrical design with a double-edged cutting head that is formed from two spiralled flutes that extend the length of the insertion part of the drill. At the proximal end, its shaft is mounted into a surgical power tool or a surgical hand drill/brace. This is a single-use device intended to be sterilized prior to use.
Obsolete false
61689 Internal orthopaedic fixation system, plate/screw, non-bioabsorbable, non-sterile
A non-sterile assembly of implantable devices designed for the stabilization of fractured/surgically-cut bones of the limbs (long bones), their appendages (hands, feet), pelvis, craniomaxillofacial bones, and/or for limb-joint fusion. It typically consists of a set of bone fixation plates, screws, wires, and pins made of materials that cannot be chemically degraded or absorbed via natural body processes (e.g., implant grade metal, surgical steel, titanium alloy, or carbon fibre). It may also include instruments for the attachment of the implants such as screwdrivers or drills. This device is intended to be sterilized prior to use.
Obsolete false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
HWC Screw, Fixation, Bone
HRS Plate, Fixation, Bone
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Moist Heat or Steam Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Outer Diameter: 2.0 Millimeter
Length: 100 Millimeter
CLOSE

Device Record Status

4a94589e-cb0a-4720-b8cc-f5605e2c73da
February 19, 2024
2
December 17, 2018
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
No
No CLOSE

Customer Contact

[?]
786-422-1400
customerservice@miamidevicesolutions.com
CLOSE