DEVICE: microTargeting™ Insertion Tube (10873263001186)

Device Identifier (DI) Information

microTargeting™ Insertion Tube
FC7140LI-00118
Not in Commercial Distribution
FC7140LI
FHC, INC.
10873263001186
GS1
January 10, 2023
5
108179458 *Terms of Use
microTargeting Lead Insertion Tube with Stylet, 5x, Sterile, Array for use with NexFrame and mT Drive.
CLOSE

Device Characteristics

MR Unsafe
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
61964 Intracerebral cannula, implantable
A sterile, implantable tube intended to be surgically placed in a specific area of the brain (e.g., basal ganglia) to position a deep brain electrical stimulation lead/electrode, using a stereotactic surgery system, and to function as a guide for subsequent and regular placement and/or removal of the lead/electrode. It is made of synthetic polymer materials (e.g., polyurethane) and may include a stylet/trocar blade.
Active true
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
HAW Neurological stereotaxic Instrument
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K011775 000
No CLOSE

Sterilization

Yes
Yes
Sterilization Method [?]
Moist Heat or Steam Sterilization
Ethylene Oxide
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Humidity: between 0 and 95 Percent (%) Relative Humidity
Storage Environment Humidity: between 0 and 95 Percent (%) Relative Humidity
Storage Environment Temperature: between 0 and 40 Degrees Celsius
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Length: 225.35 Millimeter
Outer Diameter: 1.83 Millimeter
Lumen/Inner Diameter: 1.6 Millimeter
CLOSE

Device Record Status

638144d4-ac23-449e-ab08-fafe2fd26e0d
January 10, 2023
5
August 22, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: 00873263001189 CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
+1(800)326-2905
fhcinc@fh-co.com
CLOSE