DEVICE: microTargeting™ STar™ Insertion Tube (10873263001193)

Device Identifier (DI) Information

microTargeting™ STar™ Insertion Tube
FC8009-00119
Not in Commercial Distribution
FC8009
FHC, INC.
10873263001193
GS1
January 10, 2023
5
108179458 *Terms of Use
microTargeting STar Drive Array Electrode Insertion Tube Set with Stylet, 5x, Sterile, for use with a Stereotactic Frame. Each Kit Contains: (1) IT(AR16) Insertion Tube Guide - 1.83mm OD, 0.96mm ID (does not enter brain) (1) IT(AR17) Insertion Tube w/ Stylet - 241.5mm tube length, 0.90mm tube OD, 0.60mm tube ID
CLOSE

Device Characteristics

MR Unsafe
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
61964 Intracerebral cannula, implantable
A sterile, implantable tube intended to be surgically placed in a specific area of the brain (e.g., basal ganglia) to position a deep brain electrical stimulation lead/electrode, using a stereotactic surgery system, and to function as a guide for subsequent and regular placement and/or removal of the lead/electrode. It is made of synthetic polymer materials (e.g., polyurethane) and may include a stylet/trocar blade.
Active true
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
HAW Neurological stereotaxic Instrument
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K092562 000
No CLOSE

Sterilization

Yes
Yes
Sterilization Method [?]
Ethylene Oxide
Moist Heat or Steam Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Humidity: between 0 and 95 Percent (%) Relative Humidity
Storage Environment Temperature: between 0 and 40 Degrees Celsius
Storage Environment Humidity: between 0 and 95 Percent (%) Relative Humidity
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

9f58dfb8-8043-4ba1-aee6-01f43a516216
January 10, 2023
5
August 22, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: 00873263001196 CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
+1(800)326-2905
fhcinc@fh-co.com
CLOSE