DEVICE: microTargeting™ Electrode (10873263007447)
Device Identifier (DI) Information
microTargeting™ Electrode
MTDWXN(AR)(MP1)-00744
In Commercial Distribution
MTDWXN(AR)(MP1)
FHC, INC.
MTDWXN(AR)(MP1)-00744
In Commercial Distribution
MTDWXN(AR)(MP1)
FHC, INC.
microTargeting™ Electrode, differential, tungsten, nonsterile
Device Characteristics
MR Unsafe | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
32556 | Depth electrode |
An electrical conductor intended to be temporarily placed (< 30 days) beneath the surface of the brain to stimulate the brain or to record the brain's electrical activity (with more precise localization than a scalp electrode). It is typically a fine, flexible plastic device attached to wires that carry currents from deep and superficial brain structures. The wires are connected to recording, monitoring, or stimulation/response devices [e.g., electroencephalograph (EEG), evoked-potential recorder, stimulator]. The implant is particularly helpful in determining site of origin in temporal and frontal lobe epilepsy. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
GZL | ELECTRODE, DEPTH |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K033173 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between 0 and 40 Degrees Celsius |
Storage Environment Humidity: less than 95 Percent (%) Relative Humidity |
Clinically Relevant Size
[?]Size Type Text |
---|
Lumen/Inner Diameter: 0.55 Millimeter |
Length: 220.72 Millimeter |
Length: 205.72 Millimeter |
Length: 10 Millimeter |
Device Record Status
a3749e7b-50e1-4d35-b9a6-0e6eda57ba21
September 23, 2019
2
June 05, 2019
September 23, 2019
2
June 05, 2019
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
00873263007440