DEVICE: microTargeting™ Insertion Tube (10873263007645)
Device Identifier (DI) Information
microTargeting™ Insertion Tube
FC7140LI-00764
In Commercial Distribution
FC7140LI
FHC, INC.
FC7140LI-00764
In Commercial Distribution
FC7140LI
FHC, INC.
microTargeting Lead Insertion Tube with Stylet, 5x, Sterile, Array for use with NexFrame and mT Drive.
Device Characteristics
MR Unsafe | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
62753 | Intracerebral cannula, nonimplantable, single-use |
A sterile, nonimplantable, rigid tube intended to be surgically inserted through the skull to access the brain (e.g., cerebral ventricles) for cerebrospinal fluid (CSF) drainage, infusion of materials, and/or for use as a port through which instruments, leads and/or probes can be passed to perform a variety of diagnostic, treatment, or surgical procedures. It is usually made of metal (e.g., stainless steel) and may include a stylet/trocar blade. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
HAW | Neurological stereotaxic Instrument |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K011775 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between 0 and 40 Degrees Celsius |
Handling Environment Humidity: between 0 and 95 Percent (%) Relative Humidity |
Storage Environment Humidity: between 0 and 95 Percent (%) Relative Humidity |
Clinically Relevant Size
[?]Size Type Text |
---|
Outer Diameter: 1.83 Millimeter |
Length: 225.35 Millimeter |
Lumen/Inner Diameter: 1.6 Millimeter |
Device Record Status
86e8604d-f523-4bd5-923e-c70c8f7f0ada
January 06, 2020
1
December 27, 2019
January 06, 2020
1
December 27, 2019
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
00873263007648
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)326-2905
fhcinc@fh-co.com