DEVICE: ClosureFast (10884521174924)
Device Identifier (DI) Information
ClosureFast
CF7-3-60
In Commercial Distribution
Covidien LP
CF7-3-60
In Commercial Distribution
Covidien LP
Endovenous Radiofrequency Ablation (RFA) Catheter,3 cm Heating Element,7 Fr/Ch (2.3 mm) x 60 cm
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
Yes | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
62233 | Peripheral vascular electrocautery catheter, single-use |
A flexible catheter with a distal heating element/electrode intended to be connected to an electrical generator and introduced into the peripheral vasculature to ablate venous tissues, through direct application of heat, as a treatment for venous reflux disease (varicose veins); it is not intended to introduce electrical current into the body. It is a luminal device with a proximal handle with controls (e.g., on/off switch) that is introduced via an introducer assembly (which may be included), and is typically maneuvered under external image guidance [e.g., ultrasound (US)]. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
GEI | ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K111887 | 000 |
K223488 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Temperature: between -20 and 140 Degrees Fahrenheit |
Storage Environment Humidity: between 15 and 90 Percent (%) Relative Humidity |
Handling Environment Temperature: between -20 and 140 Degrees Fahrenheit |
Handling Environment Humidity: between 15 and 90 Percent (%) Relative Humidity |
Clinically Relevant Size
[?]Size Type Text |
---|
Length: 60 Centimeter |
Catheter Gauge: 7 French |
Device Record Status
fe34249e-c793-4eb2-8049-2f442989ed72
June 24, 2025
11
September 24, 2016
June 24, 2025
11
September 24, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(508)261-8000
covidien.udi@covidien.com
covidien.udi@covidien.com