DEVICE: Nellcor (10884521582514)
Device Identifier (DI) Information
Nellcor
DS10076644
Not in Commercial Distribution
DS10076644
Covidien LP
DS10076644
Not in Commercial Distribution
DS10076644
Covidien LP
SpO2 Module Interface Cable Included
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
36554 | Patient monitoring system module, pulse oximetry |
A small unit dedicated to the transcutaneous measurement of haemoglobin oxygen saturation (SpO2) in blood using light detection methods (spectrophotometry) after light is emitted from a light-emitting diode (LED) situated in the connected probe. It is designed to operate as part of a patient monitoring system enhancing the function of this system (the parent device). The module automatically plugs into the parent device when the user places it into a standardized slot in the parent device or a connected module rack. The parent device operates as a mainframe computer displaying the pulse oximetry parameters provided by this module.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
DQA | Oximeter |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K060576 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Storage Environment Atmospheric Pressure: between 11 and 107 KiloPascal |
Storage Environment Humidity: between 15 and 95 Percent (%) Relative Humidity |
Storage Environment Temperature: between -40 and 70 Degrees Celsius |
Special Storage Condition, Specify: Keep dry;AVOID DIRECT SUNLIGHT |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
c5bafa51-7ffc-40d7-9165-97d20c573b3a
June 24, 2025
6
September 24, 2016
June 24, 2025
6
September 24, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(508)261-8000
covidien.udi@covidien.com