DEVICE: Sonicision (10884521592834)
Device Identifier (DI) Information
Sonicision
SCDA26
In Commercial Distribution
Covidien LP
SCDA26
In Commercial Distribution
Covidien LP
Curved Jaw Cordless Ultrasonic Dissector
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
Yes | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
44778 | Soft-tissue ultrasonic surgical system |
An assembly of devices that converts high frequency current into ultrasonic oscillation to mechanically fragment soft-tissue cells upon contact with a vibrating tip for cutting and/or coagulating tissue during surgery, possibly in combination with irrigation and aspiration. Ongoing vibration may create heat in cells (diathermy) to increase the cutting/coagulating capacity. It typically includes an energy-producing generator with monitoring functions, a handpiece(s) with tip(s) to convert and apply the energy, connecting cables, a foot-switch as an option to regulate the energy, and possibly an integrated irrigation/suction system.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
LFL | Instrument, ultrasonic surgical |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K180149 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Handling Environment Humidity: between 15 and 90 Percent (%) Relative Humidity |
Handling Environment Temperature: between -22 and 140 Degrees Fahrenheit |
Clinically Relevant Size
[?]Size Type Text |
---|
Length: 26 Centimeter |
Device Record Status
81d0004c-ab7d-4b27-b66e-a0d270bca14f
June 13, 2025
6
August 22, 2018
June 13, 2025
6
August 22, 2018
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
20884521592831 | 6 | 10884521592834 | In Commercial Distribution | CASE |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(508)261-8000
covidien.udi@covidien.com
covidien.udi@covidien.com