DEVICE: Valleylab (10884521751132)

Device Identifier (DI) Information

Valleylab
SEA50595
In Commercial Distribution

Covidien LP
10884521751132
GS1

1
058614483 *Terms of Use
Smoke Evacuation Extension Tube 4"
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
Yes
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
46483 Surgical plume evacuation system tube
A long, hollow cylinder which, as part of a surgical plume evacuation system, is intended to be used to capture, conduct, and exhaust the plume of smoke generated during open surgical procedures in which there is tissue ablation (e.g., laser surgery, electrocautery, electrosurgical diathermy device). This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
GEI Electrosurgical, cutting & coagulation & accessories
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K182772 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Humidity: between 15 and 90 Percent (%) Relative Humidity
Handling Environment Temperature: between 10 and 40 Degrees Celsius
Storage Environment Humidity: between 15 and 90 Percent (%) Relative Humidity
Storage Environment Temperature: between -30 and 60 Degrees Celsius
Special Storage Condition, Specify: Keep Dry
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Length: 10.16 Centimeter
CLOSE

Device Record Status

3e0479d1-a66b-45eb-984e-9290c7481424
June 24, 2025
8
January 11, 2019
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
30884521751136 8 20884521751139 In Commercial Distribution CASE
20884521751139 10 10884521751132 In Commercial Distribution PACK_OR_INNER_PACK
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
+1(508)261-8000
covidien.udi@covidien.com
CLOSE