DEVICE: Valleylab (10884521767904)

Device Identifier (DI) Information

Valleylab
E3530-3
In Commercial Distribution

Covidien LP
10884521767904
GS1

1
058614483 *Terms of Use
Flexible Argon Electrode Coagulation Only
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
Yes
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
61878 Inert gas-enhanced endoscopic electrosurgical electrode, single-use
An invasive, distal component of an inert gas-enhanced electrosurgical system intended to deliver electrosurgical current within a stream of inert gas [e.g., argon (Ar), helium (He)] directly to tissues for cutting/coagulation/ablation during an endoscopic (including laparoscopic, arthroscopic) surgical procedure. It is a long thin device with no controls, typically designed as a coaxial arrangement of a monopolar electrode within a gas delivery tube/sleeve, which requires a patient contact return electrode to complete the circuit. It is available in a variety of forms (e.g., rigid laparoscopic electrode, flexible endoscopic probe). This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
GEI Electrosurgical, cutting & coagulation & accessories
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between 50 and 104 Degrees Fahrenheit
Handling Environment Temperature: between -22 and 140 Degrees Fahrenheit
Storage Environment Humidity: between 15 and 90 Percent (%) Relative Humidity
Handling Environment Humidity: between 15 and 90 Percent (%) Relative Humidity
Special Storage Condition, Specify: Keep dry
CLOSE

Clinically Relevant Size

[?]
Size Type Text
Length: 3 Inch
CLOSE

Device Record Status

7c6d2bfd-53de-4ed6-b679-ad3dab3e2da2
June 24, 2025
6
May 07, 2020
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
30884521767908 15 20884521767901 In Commercial Distribution CASE
20884521767901 10 10884521767904 In Commercial Distribution PACK_OR_INNER_PACK
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
No
No
No CLOSE

Customer Contact

[?]
+1(508)261-8000
covidien.udi@covidien.com
CLOSE