DEVICE: Edge (10884524000626)
Device Identifier (DI) Information
Edge
E2350H
In Commercial Distribution
Covidien LP
E2350H
In Commercial Distribution
Covidien LP
Rocker Switch Pencil Blade Electrode, Holster
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
57944 | Endoscopic electrosurgical handpiece/electrode, bipolar, single-use |
A sterile electrosurgical device which consists of a handpiece with mechanical and/or electrical controls, and a bipolar electrode intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation/ablation during endoscopic (including laparoscopic, arthroscopic) surgery, and may in addition be intended for open surgery; it is not intended for focal percutaneous ablation. It includes a long thin electrode connected to the handpiece, and may include a lumen for suction/irrigation; it is available in a variety of forms (e.g., forceps, rigid probe with controls). This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
GEI | ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K955836 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Handling Environment Temperature: between -22 and 140 Degrees Fahrenheit |
Special Storage Condition, Specify: Keep dry |
Clinically Relevant Size
[?]Size Type Text |
---|
Length: 10 Feet |
Device Record Status
0a27b776-1a7c-4e03-8041-e90b2cc9c166
September 19, 2023
8
September 24, 2016
September 19, 2023
8
September 24, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
30884524000620 | 50 | 10884524000626 | In Commercial Distribution | CASE |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(508)261-8000
covidien.udi@covidien.com
covidien.udi@covidien.com