DEVICE: NA (10886704044086)

Device Identifier (DI) Information

NA
IP-37957
In Commercial Distribution
IP37957
Medos International Sàrl
10886704044086
GS1
July 28, 2025
1
482661753 *Terms of Use
FOR USE WITH: CODMAN 3000 Series Tapered Silicone Rubber Catheter (Radiopaque) with Connector Contents: (1) Catheter: O.D. 2.3mm tapered to O.D. 1.5mm x I.D. 0.6mm x 51.7cm long with (1) Universal Barbed Connector
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
Yes
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
61493 Spinal port/catheter
A sterile implantable device intended to provide access to the subarachnoid (intrathecal) space of the spinal column for infusion (e.g., chemotherapeutic agents, pain relieving drugs) and/or drainage [e.g., cerebrospinal fluid (CSF)]. It consists of a subcutaneous chamber, with a self-sealing puncturable septum for percutaneous insertion of a hypodermic needle, attached to a distal catheter which passes into the target site. It is made of metal [e.g., titanium (Ti)] and synthetic polymers (e.g., silicone); disposable devices associated with implantation may be included.
Active true
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
LKK PUMP, INFUSION, IMPLANTED, PROGRAMMABLE
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
P800036 037
P890055 016
P890055 017
P890055 021
P890055 023
P890055 027
P890055 038
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Temperature: between 15 and 25 Degrees Celsius
Storage Environment Temperature: between 15 and 25 Degrees Celsius
Handling Environment Temperature: between 59 and 77 Degrees Fahrenheit
Storage Environment Temperature: between 59 and 77 Degrees Fahrenheit
Special Storage Condition, Specify: Do not use if opened or damaged.
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

05fa21a5-42b0-4079-8931-cfbe37692bbe
January 28, 2022
5
September 20, 2014
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
+1(800)255-2500
xx@xx.xx
CLOSE