DEVICE: CODMAN HAKIM RICKHAM SIPHONGUARD (10886704045458)

Device Identifier (DI) Information

CODMAN HAKIM RICKHAM SIPHONGUARD
NS0391
Not in Commercial Distribution
NS0391
Cerenovus, Inc.
10886704045458
GS1
September 01, 2022
1
607846297 *Terms of Use
CODMAN HAKIM Precision Fixed Pressure Valve MICRO II With RICKHAM Reservoir and SIPHONGUARD Device Operating Pressure: 40mm H2O Plus or Minus 10mm H2O (392 Pa Plus or Minus 98 Pa) Low Range Includes: Ventricular Catheter 14cm, Stylet, Nonunitized Peritoneal Catheter 120cm, Priming Adapter and Information Manual
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
45694 Ventriculoperitoneal shunt
An implantable device intended to divert excessive cerebrospinal fluid (CSF) from the brain ventricles to the peritoneal cavity, where it can be absorbed into the body, as a treatment for increased intracranial pressure (e.g., caused by hydrocephalus). It typically consists of three main connected parts: 1) an intracerebral ventricular catheter through which CSF flows; 2) a mechanical shunt valve that typically opens at a pre-set pressure; and 3) a peritoneal catheter that channels the CSF to the peritoneal cavity. It is made of plastic and silicone materials; disposable devices associated with implantation may be included.
Active true
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
JXG Shunt, central nervous system and components
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K091346 000
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

b086ca75-8ea3-4385-86a6-5277756d95d3
September 15, 2023
7
September 20, 2015
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
+1(800)255-2500
xx@xx.xx
CLOSE