DEVICE: CERENOVUS ENTERPRISE (10886704075356)
Device Identifier (DI) Information
CERENOVUS ENTERPRISE
ENF402312
In Commercial Distribution
ENF402312
Medos International Sàrl
ENF402312
In Commercial Distribution
ENF402312
Medos International Sàrl
CERENOVUS ENTERPRISE 2 Vascular Reconstruction Device Stent OD (mm) 4.0 Stent Length (mm) 23 Recommended Microcatheter .021 Inch (0.533mm) Maximum Stent Foreshortening 2.0 mm Humanitarian Device USA ONLY): Authorized by Federal Law for use with embolic coils for the treatment of wide-neck, intracranial, saccular, or fusiform aneurysms arising from a parent vessel with a diameter of greater than or equal to 2.5mm and less than or equal to 4mm. Wide-neck is defined as having a neck width greater than or equal to 4mm or a dome-to-neck ratio less than 2mm. The effectiveness of this device for this use has not been demonstrated.
Device Characteristics
MR Conditional | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
46352 | Bare-metal intracranial vascular stent |
A non-bioabsorbable tubular device typically intended to be implanted into the base or parent artery of an intracranial aneurysm (e.g., wide-neck aneurysm situated at the base of a bifurcation) to facilitate the delivery of embolics to fill the aneurysm, facilitate clotting within the aneurysm by slowing blood flow into it, and/or to provide support for a neurovascular embolization coil placed inside the aneurysm. It is made of uncoated metal [e.g., nickel-titanium alloy (Nitinol)] and self-expands after it is delivered to the site of implantation and released (e.g., from a dedicated delivery instrument). Disposable devices associated with implantation may be included.
|
Active | true |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
NJE | intracranial neurovascular stent |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
H060001 | 015 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
06e04802-2e46-4116-83fc-f13719e3f5d1
February 05, 2021
5
November 16, 2015
February 05, 2021
5
November 16, 2015
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)255-2500
xx@xx.xx
xx@xx.xx