DEVICE: CERENOVUS ENTERPRISE (10886704075356)

Device Identifier (DI) Information

CERENOVUS ENTERPRISE
ENF402312
In Commercial Distribution
ENF402312
Medos International Sàrl
10886704075356
GS1

1
482661753 *Terms of Use
CERENOVUS ENTERPRISE 2 Vascular Reconstruction Device Stent OD (mm) 4.0 Stent Length (mm) 23 Recommended Microcatheter .021 Inch (0.533mm) Maximum Stent Foreshortening 2.0 mm Humanitarian Device USA ONLY): Authorized by Federal Law for use with embolic coils for the treatment of wide-neck, intracranial, saccular, or fusiform aneurysms arising from a parent vessel with a diameter of greater than or equal to 2.5mm and less than or equal to 4mm. Wide-neck is defined as having a neck width greater than or equal to 4mm or a dome-to-neck ratio less than 2mm. The effectiveness of this device for this use has not been demonstrated.
CLOSE

Device Characteristics

MR Conditional
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
46352 Bare-metal intracranial vascular stent
A non-bioabsorbable tubular device typically intended to be implanted into the base or parent artery of an intracranial aneurysm (e.g., wide-neck aneurysm situated at the base of a bifurcation) to facilitate the delivery of embolics to fill the aneurysm, facilitate clotting within the aneurysm by slowing blood flow into it, and/or to provide support for a neurovascular embolization coil placed inside the aneurysm. It is made of uncoated metal [e.g., nickel-titanium alloy (Nitinol)] and self-expands after it is delivered to the site of implantation and released (e.g., from a dedicated delivery instrument). Disposable devices associated with implantation may be included.
Active true
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
NJE intracranial neurovascular stent
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
H060001 015
No CLOSE

Sterilization

Yes
No
Sterilization Method [?]
No Sterilization Methods Found
CLOSE

Storage and Handling

[?]
Storage and Handling
No storage/handling found
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

06e04802-2e46-4116-83fc-f13719e3f5d1
February 05, 2021
5
November 16, 2015
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
+1(800)255-2500
xx@xx.xx
CLOSE