DEVICE: ThinPrep 3000 Processor (15420045500846)
Device Identifier (DI) Information
ThinPrep 3000 Processor
ThinPrep 3000 Processor
Not in Commercial Distribution
70150-001
Hologic, Inc.
ThinPrep 3000 Processor
Not in Commercial Distribution
70150-001
Hologic, Inc.
Processes liquid based cytologic specimens to produce a uniform layer of cells on a glass microsope slide.
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
No | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
15110 | Microscope slide maker IVD |
An electrically-powered automated or semi-automated laboratory instrument intended to be used to prepare, transfer and/or fix blood, tissue, cytology specimens, or other clinical specimens onto microscope examination slides so they are suitable for subsequent staining and/or microscopic analysis.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
MKQ | Processor, cervical cytology slide, automated |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
P950039 | 028 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Handling Environment Temperature: between 16 and 32 Degrees Celsius |
Storage Environment Humidity: between 15 and 95 Percent (%) Relative Humidity |
Storage Environment Temperature: between -28 and 50 Degrees Celsius |
Handling Environment Humidity: between 20 and 80 Percent (%) Relative Humidity |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
bd7fc24e-e1b5-4992-b02b-c9a58522ca65
November 07, 2024
6
September 02, 2014
November 07, 2024
6
September 02, 2014
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)442-9892
CustomerSupport@hologic.com
CustomerSupport@hologic.com