DEVICE: ACUCISE® PROCEDURAL PACK UNIVERSAL PACK A (20607915128122)
Device Identifier (DI) Information
ACUCISE® PROCEDURAL PACK UNIVERSAL PACK A
BK002
Not in Commercial Distribution
APPLIED MEDICAL RESOURCES CORPORATION
BK002
Not in Commercial Distribution
APPLIED MEDICAL RESOURCES CORPORATION
Kit Contains:
B1005, ACUCISE® ENDOPYELOTOMY SYSTEM
B3301, STENT, C-FLEX, 7/10F X 26CM
B7016, FORTE AxP SET 12/14/18F 35CM 6/BX
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
Yes | |
Yes | |
Yes | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
47053 | Ureteral stent-placement set |
A collection of devices used to facilitate the implantation of a ureteral stent, via the natural orifice or percutaneously through a tortuous ureter, in order to maintain ureteral patency. The devices are typically made of high-grade stainless steel and/or a polymer [e.g., polyvinyl chloride (PVC)] and typically include a guidewire, a dilator, a positioner, an inserter, a placement catheter, an introduction sheath, and a release sleeve. Some of the devices may be radiopaque, and may have Luer connectors at the proximal end to allow for the injection of a contrast medium. This is a single-use device.
|
Active | false |
58005 | Polymeric ureteral stent |
A sterile non-bioabsorbable tubular device intended to be implanted in an obstructed ureter (e.g., from stone, stricture, compression, fibrosis, trauma) to maintain luminal patency allowing urine to drain from the renal pelvis to the bladder. It is made of a synthetic polymer(s) [e.g., polytetrafluoroethylene (PTFE), polyethylene (PE), silicone], sometimes with a hydrophilic coating (e.g., hydrogel), and may have various designs (e.g., continuous tube with or without drainage side holes, covered or non-covered mesh structure). Disposable devices intended to assist implantation may be included. The device is typically intended for long-term, but not permanent, implantation.
|
Active | true |
34926 | Ureteral catheter |
A flexible tube designed for introduction into the ureters through a cystoscope, ureteroscope or nephroscope. It is typically a 3 to 12 Fr radiopaque tube with one of several tip configurations (e.g., straight, bent, olive). It may have a single or double-lumen and graduated markings. The device is used for ureter dilation, bypass of partial obstructions, urinary tract irrigation/drainage during surgery (e.g., injection of contrast agent, anaesthetic agent and/or antiretropulsion gel), stone removal, retrograde urography, guidewire placement, and/or brush biopsy. This is a single-use device.
|
Active | false |
46691 | Gastro-urological guidewire, single-use |
A metal coil or wire intended to assist the insertion/positioning of a diagnostic/therapeutic device(s) [e.g., endoscope, catheter] within the gastrointestinal (GI) and/or urinary tract. It is typically coated with a plastic material [e.g., polytetrafluoroethylene (PTFE), commonly known as Teflon, or polyethylene (PE)]. It may have radiopaque graduated markings at the distal end to assist in the fluoroscopic monitoring of its advancement/position within the body. This is a single-use device.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
KNY | Accessories, Catheter, G-U |
EZB | Stylet For Catheter, Gastro-Urology |
DXT | Injector And Syringe, Angiographic |
EYB | Catheter, Ureteral, Gastro-Urology |
FED | Endoscopic Access Overtube, Gastroenterology-Urology |
FAD | Stent, Ureteral |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
c0768e88-b379-465a-a186-4199954f342a
December 23, 2024
5
October 09, 2015
December 23, 2024
5
October 09, 2015
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
1.949.713.8300
contact@appliedmedical.com
contact@appliedmedical.com