DEVICE: MIGS Kit 1 (20607915139142)
Device Identifier (DI) Information
MIGS Kit 1
GK158
In Commercial Distribution
APPLIED MEDICAL RESOURCES CORPORATION
GK158
In Commercial Distribution
APPLIED MEDICAL RESOURCES CORPORATION
Kit contains:
C8403, Large Alexis O Wound Protector/Retractor
EB040, Voyant Open Fusion
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
47431 | Radial surgical retractor |
A sterile surgical device intended to be inserted across a surgical incision to separate the margins of the incision to create a conduit to the underlying organs/tissues during hand-assisted minimally-invasive and open surgery. It consists of an external and internal fixed or retracting ring interconnected with an elastomeric sleeve/sheath intended to also provide protection against wound contamination, and may include channels/tubing to allow wound-edge irrigation. Also known as a lap disc, hand access device, handport, or protector, it may be used with or without a seal cap for colorectal, urological, gynaecological, or general abdominal surgical procedures. This is a single-use device.
|
Active | false |
44776 | Electrosurgical system |
An assembly of devices intended to generate, and apply radio-frequency (RF) alternating current to soft tissues for cutting and coagulation during an endoscopic or open surgical procedure; it is not dedicated to focal ablation of specific tissues (i.e., not a radio-frequency ablation system). The assembly includes a mains electricity-powered (AC-powered) RF generator with monitoring functions/controls, connection cables, a handpiece, and electrodes to apply the energy to the surgical site. Tissue resistance to the electrical current creates the heat as the current travels through the body between electrodes; it is not intended for inert gas-enhanced electrosurgery.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
GEI | Electrosurgical, Cutting & Coagulation & Accessories |
KGW | Ring (Wound Protector), Drape Retention, Internal |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
772352db-79ea-46f0-b668-30209917d47f
April 04, 2023
2
May 09, 2018
April 04, 2023
2
May 09, 2018
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
1-949-713-8300
contact@appliedmedical.com
contact@appliedmedical.com