DEVICE: MIGS KIT 3 (20607915139159)
Device Identifier (DI) Information
MIGS KIT 3
GK160
In Commercial Distribution
APPLIED MEDICAL RESOURCES CORPORATION
GK160
In Commercial Distribution
APPLIED MEDICAL RESOURCES CORPORATION
Kit contains:
(1) GTB17, Alexis Contained Extraction System, 17cm
(1) C0R47, 12x100mm Kii Balloon Blunt Tip System
(3) CFF03, 5x100mm Kii Fios First Entry, Advanced Fixation
(1) EB010, Voyant 5mm Fusion Device, 37cm
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
42412 | Laparoscopic access cannula, single-use |
A single-lumen surgical device intended to be percutaneously inserted through the abdominal wall to create an access port for a laparoscope/laparoscopic instrument during laparoscopy. The cannula is provided with a shut-off valve for gas/fluid supply, and other sealing devices (e.g., dedicated seals/rings, caps, valves), to prevent insufflation gas leakage whilst allowing entry of instruments; it may additionally be intended for thoracoscopy whereby the valve may not be required. It may include a sharp or blunt trocar blade to assist introduction and/or puncture the abdominal wall; if the trocar is included it may be referred to as a trocar or trocar assembly. This is a single-use device.
|
Active | false |
45130 | Tissue extraction bag |
An impervious, flexible, sterile container intended to be used during minimally-invasive, typically keyhole, surgical techniques (e.g., laparoscopic) to extract dissected patient body tissue. The device is inserted into the body through a large bore cannula port, and the tissue to be extracted is placed in the bag with trans-cannula instruments and evacuated through the cannula. The device typically includes an x-ray detectable thread. This device may be used for surgical interventions such as an appendectomy, colonectomy, lymphadenectomy, or gallbladder removal. This is a single-use device.
|
Active | false |
44776 | Electrosurgical system |
An assembly of devices intended to generate, and apply radio-frequency (RF) alternating current to soft tissues for cutting and coagulation during an endoscopic or open surgical procedure; it is not dedicated to focal ablation of specific tissues (i.e., not a radio-frequency ablation system). The assembly includes a mains electricity-powered (AC-powered) RF generator with monitoring functions/controls, connection cables, a handpiece, and electrodes to apply the energy to the surgical site. Tissue resistance to the electrical current creates the heat as the current travels through the body between electrodes; it is not intended for inert gas-enhanced electrosurgery.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
GEI | Electrosurgical, Cutting & Coagulation & Accessories |
GCJ | Laparoscope, General & Plastic Surgery |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
6756ec74-4f06-4695-bb54-3476c3ecdf29
April 04, 2023
3
May 09, 2018
April 04, 2023
3
May 09, 2018
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
1-949-713-8300
contact@appliedmedical.com
contact@appliedmedical.com