DEVICE: MICROLAP (20653405006098)

Device Identifier (DI) Information

MICROLAP
C-LIL-H-RP1
Not in Commercial Distribution
C-LIL-H-RP1
Conmed Corporation
20653405006098
GS1
June 25, 2022
1
071595540 *Terms of Use
10653405006091
MicroLap Red Peek Handle
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
No
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
33596 Endoscopic electrosurgical handpiece/electrode, monopolar, reusable
An electrosurgical device which consists of a handpiece with mechanical and/or electrical controls, and a monopolar electrode, intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation/ablation during endoscopic (including laparoscopic, arthroscopic) surgery. It includes a long thin electrode connected to the handpiece, and may include a lumen for suction/irrigation; it is available in a variety of forms (e.g., forceps or snare with ring handles, rigid probe with controls) and requires a patient contact return electrode to complete the circuit. This is a reusable device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
GCJ Laparoscope, general & plastic surgery
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
K140101 000
No CLOSE

Sterilization

No
Yes
Sterilization Method [?]
Moist Heat or Steam Sterilization
CLOSE

Storage and Handling

[?]
Storage and Handling
Handling Environment Temperature: between 50 and 90 Degrees Fahrenheit
Storage Environment Temperature: between 50 and 90 Degrees Fahrenheit
Handling Environment Humidity: between 30 and 80 Percent (%) Relative Humidity
Handling Environment Temperature: between 10 and 32 Degrees Celsius
Storage Environment Temperature: between 10 and 32 Degrees Celsius
Storage Environment Humidity: between 30 and 90 Percent (%) Relative Humidity
Special Storage Condition, Specify: KEEP DRY
Special Storage Condition, Specify: KEEP AWAY FROM SUNLIGHT
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

3014880c-b783-4be1-8999-9b8f0a19b50f
June 28, 2022
2
December 02, 2020
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
No Package DIs found
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: No Unit of Use DI Numbers Found CLOSE

Direct Marking (DM)

[?]
No
Yes
30653405006095
CLOSE

Production Identifier(s) in UDI

[?]
No
Yes
No
Yes
No CLOSE

Customer Contact

[?]
+1(866)426-6633
CustomerExperience@conmed.com
CLOSE