DEVICE: DR. J. WALKER (30607915134649)
Device Identifier (DI) Information
DR. J. WALKER
K2785
In Commercial Distribution
APPLIED MEDICAL RESOURCES CORPORATION
K2785
In Commercial Distribution
APPLIED MEDICAL RESOURCES CORPORATION
Kit Contains:
CA500, EPIX® UNIVERSAL CLIP APPLIER 3/BX
CTS02, 5x100 Kii® SLEEVE ZTHR 12/BX
CD001, 10mm RETRIEVAL SYSTEM, 10/BX
C0R47, 12x100 Kii® BALLOON BLUNT TIP 6/BX
CTB03, 5x100 Kii® SH BLD ZTHR 6/BX
CB030, 5mmx35cm EPIX® LAPA SCISSOR, 10/BX
C4120, 38CM GRASPER REPOS CART, 10/BX
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
Yes | |
Yes | |
Yes | |
No | |
Yes | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
57956 | Rigid endoscopic grasping forceps, single-use |
A sterile, rigid manual device used in combination with a compatible endoscope to grasp tissue (typically atraumatically) or foreign bodies. It is typically constructed as a very long instrument with one sliding and one stationary rod whose distal ends are equipped with grasping tongs or claws which are operated by scissors-like ring handles at the proximal end of the instrument. It is typically made of metal and plastic materials and is introduced into the body through the working channel of the endoscope to grasp internal structures for observation, excision, and/or biopsy procedures. This is a single-use device.
|
Obsolete | false |
58039 | Endoscopic electrosurgical handpiece/electrode, monopolar, single-use |
A sterile electrosurgical device which consists of a handpiece with mechanical and/or electrical controls, and a monopolar electrode, intended to deliver electrosurgical current from a system generator directly to tissues for cutting/coagulation/ablation during endoscopic (including laparoscopic, arthroscopic) surgery. It includes a long thin electrode connected to the handpiece and may include a lumen for suction/irrigation; it requires a patient contact return electrode to complete the circuit. It is available in a variety of forms (e.g., forceps or snare with ring handles, rigid probe with controls) and may be designed to also mechanically cut tissues. This is a single-use device.
|
Active | false |
45130 | Tissue extraction bag |
An impervious, flexible, sterile container intended to be used during minimally-invasive, typically keyhole, surgical techniques (e.g., laparoscopic) to extract dissected patient body tissue. The device is inserted into the body through a large bore cannula port, and the tissue to be extracted is placed in the bag with trans-cannula instruments and evacuated through the cannula. The device typically includes an x-ray detectable thread. This device may be used for surgical interventions such as an appendectomy, colonectomy, lymphadenectomy, or gallbladder removal. This is a single-use device.
|
Active | false |
42412 | Laparoscopic access cannula, single-use |
A single-lumen surgical device intended to be percutaneously inserted through the abdominal wall to create an access port for a laparoscope/laparoscopic instrument during laparoscopy. The cannula is provided with a shut-off valve for gas/fluid supply, and other sealing devices (e.g., dedicated seals/rings, caps, valves), to prevent insufflation gas leakage whilst allowing entry of instruments; it may additionally be intended for thoracoscopy whereby the valve may not be required. It may include a sharp or blunt trocar blade to assist introduction and/or puncture the abdominal wall; if the trocar is included it may be referred to as a trocar or trocar assembly. This is a single-use device.
|
Active | false |
35649 | Ligation clip, metallic |
A metallic, non-bioabsorbable clasp designed to be implanted around a blood vessel, lymphatic vessel, other tubular anatomy or a tissue bundle, for permanent occlusion. It may be used for ligation in open and endoscopic (e.g., laparoscopic) surgeries; a dedicated, disposable clip applier may be included.
|
Active | true |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
NWV | Laparoscopic Accessories, Gynecologic |
HET | Laparoscope, Gynecologic (And Accessories) |
GCJ | Laparoscope, General & Plastic Surgery |
FZP | Clip, Implantable |
MDM | Instrument, Manual, Surgical, General Use |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
Premarket Submission Number Not Available/Not Released |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
No storage/handling found |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
3ab6798b-6715-4fde-a36e-a602be6013c1
February 05, 2021
5
October 16, 2015
February 05, 2021
5
October 16, 2015
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
No Package DIs found |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number:
No Unit of Use DI Numbers Found
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
1.949.713.8300
contact@appliedmedical.com
contact@appliedmedical.com