ELECTROSURGICAL SUCTION COAGULATOR 10FR
Device Characteristics
Labeling does not contain MRI Safety Information | |
No | |
No | |
Yes | |
Yes | |
No | |
No | |
No | |
No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
---|---|---|---|---|
61874 | Open-surgery electrosurgical electrode, monopolar, single-use |
An invasive, monopolar, electrical conductor intended to be attached to an appropriate handle/handpiece (not included) to deliver electrosurgical current directly to tissues for cutting/coagulation during an open surgical procedure. It may be available in a variety of forms (e.g., blade, ball, loop, needle, spatula) and requires a patient contact return electrode to complete the circuit. This is a single-use device intended to be used in a sterile condition.
|
Active | false |
FDA Product Code
[?]Product Code | Product Code Name |
---|---|
GEI | ELECTROSURGICAL, CUTTING & COAGULATION & ACCESSORIES |
FDA Premarket Submission
FDA Premarket Submission Number [?] | Supplement Number [?] |
---|---|
K033003 | 000 |
Sterilization
Storage and Handling
[?]Storage and Handling |
---|
Handling Environment Temperature: between -20 and 100 Degrees Fahrenheit |
Storage Environment Temperature: between 50 and 90 Degrees Fahrenheit |
Handling Environment Temperature: between -29 and 38 Degrees Celsius |
Handling Environment Temperature: between 100 and 131 Degrees Fahrenheit |
Storage Environment Temperature: between 10 and 32 Degrees Celsius |
Handling Environment Temperature: between 38 and 55 Degrees Celsius |
Handling Environment Humidity: between 0 and 85 Percent (%) Relative Humidity |
Storage Environment Humidity: between 5 and 60 Percent (%) Relative Humidity |
Handling Environment Humidity: between 0 and 20 Percent (%) Relative Humidity |
Clinically Relevant Size
[?]Size Type Text |
---|
No Device Sizes |
Device Record Status
5dbc29e4-de07-4826-854a-913f778fad61
September 06, 2021
5
September 24, 2016
September 06, 2021
5
September 24, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
---|---|---|---|---|---|
20653404049933 | 25 | 30653404049930 | 2021-09-04 | Not in Commercial Distribution | CARTON |
Secondary DI
[?]Issuing Agency [?] | Secondary DI Number |
---|---|
No Secondary DIs found |
Unit of Use DI
[?]
Unit of Use DI Number: