Device Identifier (DI) Information

UNIVERSAL PLUS
60-6010-002
In Commercial Distribution
60-6010-002
Conmed Corporation
30653405011709
GS1

10
071595540 *Terms of Use
UNIVERSAL PLUS MULTIFUNCTION INSTRUMENT SYSTEM (PISTOL GRIP HANDLE), ELECTROSURGICAL SUCTION/IRRIGATION INSTRUMENT WITH HAND CONTROLLED ELECTROSURGERY
CLOSE

Device Characteristics

Labeling does not contain MRI Safety Information
No
No
Yes
Yes
No
No
No
No

GMDN

[?]

GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.

GMDN Term Code GMDN Term Name GMDN Term Definition GMDN Term Status [?] Implantable?
58039 Endoscopic electrosurgical handpiece/electrode, monopolar, single-use
An electrosurgical device consisting of a handpiece with mechanical and/or electrical controls, and a monopolar electrode, intended to deliver a current from a system generator directly to tissues for cutting/coagulation/ablation during endoscopic (including laparoscopic, arthroscopic) surgery. It includes a long thin electrode connected to the handpiece and requires a patient contact return electrode; it may include a suction/irrigation lumen and may feature a magnetic guidance sensor for electromagnetic tracking. It is available in a variety of forms (e.g., forceps or snare with ring handles, rigid probe) and may also be designed to mechanically cut tissues. This is a single-use device.
Active false
CLOSE

FDA Product Code

[?]
Product Code Product Code Name
GEI Electrosurgical, cutting & coagulation & accessories
CLOSE

FDA Premarket Submission

FDA Premarket Submission Number [?] Supplement Number [?]
Premarket Submission Number Not Available/Not Released
No CLOSE

Sterilization

Yes
Yes
Sterilization Method [?]
Ethylene Oxide
CLOSE

Storage and Handling

[?]
Storage and Handling
Storage Environment Temperature: between 50 and 90 Degrees Fahrenheit
Storage Environment Temperature: between 10 and 32 Degrees Celsius
Storage Environment Humidity: between 10 and 90 Percent (%) Relative Humidity
CLOSE

Clinically Relevant Size

[?]
Size Type Text
No Device Sizes
CLOSE

Device Record Status

bd78b927-1a52-4cd8-bd04-6360c5e62419
August 07, 2024
7
September 24, 2016
CLOSE

Alternative and Additional Identifiers Additional Identifiers

Package DI

[?]
Package DI Number Quantity per Package Contains DI Package Package Discontinue Date Package Status Package Type
20653405011702 10 30653405011709 In Commercial Distribution BOX
CLOSE

Secondary DI

[?]
Issuing Agency [?] Secondary DI Number
No Secondary DIs found
CLOSE

Unit of Use DI

[?]
Unit of Use DI Number: 00653405011708 CLOSE

Direct Marking (DM)

[?]
No
No
None
CLOSE

Production Identifier(s) in UDI

[?]
Yes
No
Yes
No
No CLOSE

Customer Contact

[?]
+1(866)426-6633
CustomerExperience@conmed.com