DEVICE: NA (30653405038294)
Device Identifier (DI) Information
NA
60-6045-002
Not in Commercial Distribution
60-6045-002
Conmed Corporation
60-6045-002
Not in Commercial Distribution
60-6045-002
Conmed Corporation
5MM X 33CM CURVED (MARYLAND) TIP MONOPOLAR GRASPER
Device Characteristics
| Labeling does not contain MRI Safety Information | |
| No | |
| No | |
| Yes | |
| Yes | |
| No | |
| No | |
| No | |
| No |
GMDN
[?]GMDN© Term Code, Names and Definitions (*Terms of Use): GMDN® is a registered trademark of The GMDN Agency. All rights reserved. Used under licence from The GMDN Agency Ltd.
| GMDN Term Code | GMDN Term Name | GMDN Term Definition | GMDN Term Status [?] | Implantable? |
|---|---|---|---|---|
| 61874 | Open-surgery electrosurgical electrode, monopolar, single-use |
An invasive, monopolar, electrical conductor intended to be attached to an appropriate handle/handpiece (not included) to deliver electrosurgical current directly to tissues for cutting/coagulation during an open surgical procedure. It may be available in a variety of forms (e.g., blade, ball, loop, needle, spatula) and requires a patient contact return electrode to complete the circuit. This is a single-use device intended to be used in a sterile condition.
|
Active | false |
FDA Product Code
[?]| Product Code | Product Code Name |
|---|---|
| GCJ | Laparoscope, general & plastic surgery |
FDA Premarket Submission
| FDA Premarket Submission Number [?] | Supplement Number [?] |
|---|---|
| K943327 | 000 |
Sterilization
Storage and Handling
[?]| Storage and Handling |
|---|
| Handling Environment Humidity: between 30 and 75 Percent (%) Relative Humidity |
| Storage Environment Temperature: between 50 and 90 Degrees Fahrenheit |
| Handling Environment Temperature: between 60 and 80 Degrees Fahrenheit |
| Handling Environment Temperature: between 16 and 27 Degrees Celsius |
| Storage Environment Humidity: between 10 and 90 Percent (%) Relative Humidity |
| Handling Environment Temperature: between -29 and 60 Degrees Celsius |
| Handling Environment Temperature: between -20 and 140 Degrees Fahrenheit |
| Storage Environment Temperature: between 10 and 32 Degrees Celsius |
| Handling Environment Humidity: less than 85 Percent (%) Relative Humidity |
Clinically Relevant Size
[?]| Size Type Text |
|---|
| Outer Diameter: 5 Millimeter |
| Length: 33 Centimeter |
Device Record Status
3462e5bd-20b6-4d96-8921-b433102471b1
October 17, 2024
6
September 24, 2016
October 17, 2024
6
September 24, 2016
Alternative and Additional Identifiers Additional Identifiers
Package DI
[?]| Package DI Number | Quantity per Package | Contains DI Package | Package Discontinue Date | Package Status | Package Type |
|---|---|---|---|---|---|
| 20653405038297 | 5 | 30653405038294 | 2024-10-16 | Not in Commercial Distribution | BOX |
Secondary DI
[?]| Issuing Agency [?] | Secondary DI Number |
|---|---|
| No Secondary DIs found | |
Unit of Use DI
[?]
Unit of Use DI Number:
00653405038293
CLOSE
Direct Marking (DM)
[?]Production Identifier(s) in UDI
[?]Customer Contact
[?]
+1(800)237-0169
CUSTOMER_SERVICE@CONMED.COM
CUSTOMER_SERVICE@CONMED.COM